11/10/2023 0 Comments Aili battery monitor extension cableIf you are not sure how something should be fused, ask. Whenever you see a diagram from any of us, don't assume the fusing is correct. There have been complaints about not showing proper fusing in diagrams so I am trying (and typically failing) to remember to do that. Without the device fuse the tiny wire could become a very smoky fire-prone fuse. The main fuse would not even notice a short on the tiny wire going to the shunt. Notice that the tiny positive wire to the shunt is fused seperately. (I started with a drawing I had from helping another guy that had the fuse on the negative.) Here is how I more typically would do it: Display voltage, current, ampere-hours, state of charge (SOC), time to go, and power consumption in watts. That works but I typically put the fuse/breaker on the positive side. AiLi 500A Battery Monitor High Low Voltage and Low Capacity Programmable Alarm Compatible with 10-120V Lithium Sealed Gel Flooded Batteries Capacity up to 9999 Ah. (They should be the same gauge as the positive wire to the device) You should at least consider doing it for any high current devices you might have on the circuit.īTW: In my drawing above, I notice I show the fuse on the negative side. The Aili Battery monitor does its magic by measuring. You may want to consider adding a negative return wire for all of your other devices as well. The manual sheet included with the Aili Battery Monitor Click on the orange button in the upper right of this screen to get the manual Brief Description of how the Aili battery monitor works. That is good but it needs to be to the P- of the shunt, not B. If I am understanding your set-up you are putting a heavy gauge wire between the inverter and the battery negative. That means the shunt is measuring the current to/from all of the devices except the inverter.Īs a side note: chassis ground is not typically considered a good path for the negative connections to appliances/devices. Yes, the P- will typically go to chassis and, in you case it sounds like that is also the negative return for all of your devices except your inverter. If it is on the B- side of the shunt, the shunt can not measure current going to/from the inverter. 1 Hello I am a newbi here and my knowledge is not 0 but defiantly a novias. Is the inverter negative on the B- or P- side of the shunt. Click to expand.Please provide a diagram of your set-up. Extension cable for AiLi Battery Monitor 80V100A (ASIN: B07CTKYFTG ) / 80V350A (ASIN: B07FGFFHC6).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |